ISO 9001:2015 CERTIFIED Factory: Mundka Udyog Nagar Industrial Area, New Delhi 110041 | H.O.: Moti Nagar, New Delhi | Direct Factory Rates & Free CAD Site Survey
Direct Factory Supply | Mundka, West Delhi

Industrial Cable Raceways & Wireways Manufacturer in Delhi NCR

Availability: In Stock
₹280 – ₹850 per running meter (indicative)
Direct Factory Supply from Mundka Plant | Free 2D/3D CAD Layout
  • Types: Enclosed sheet metal electrical wireways, floor trunking, and wall-mounted cable raceways
  • Material: Pre-Galvanized (GI), Cold-Rolled CRCA, and Stainless Steel (SS304/SS316)
  • Covers: Screw-fix or snap-on removable covers with continuous earthing connections
  • Protection: IP40 to IP54 ingress protection against dust, rodents, and mechanical impacts
Raceways Manufacturer Mundka Delhi | Vaishno Storage Solution
ISO 9001:2015 Certified
Prime IS 2062 Structural Steel
North India Delivery
Direct Mundka Factory Dispatch
Free Site Inspection
Delhi NCR Warehouse Layouts
24-Hr Quotation
Fast Technical CAD Estimation
Trusted by 100+ Warehouses & Industrial Plants Across North India
Star Labs Client Logo Star Labs
APT Client Logo APT
Adani Defence and Aerospace Client Logo Adani Defence and Aerospace
Globe Moving Client Logo Globe Moving
Unilever Nepal Limited Client Logo Unilever Nepal Limited
Nepal Electricity Authority Client Logo Nepal Electricity Authority
Coca Cola Client Logo Coca Cola
Mangalam Group Client Logo Mangalam Group
MAW Building Trust Through Service Client Logo MAW Building Trust Through Service
CG Motors Client Logo CG Motors
Save the Children Client Logo Save the Children
USAID Client Logo USAID
Technical Overview

Raceways Engineering & System Operation

What is Raceways? Industrial cable raceways are fully enclosed steel trunking channels with removable snap-on or screwed covers, designed to organize and protect electrical power distribution and network data cabling across commercial buildings and plants.

Where is it Used? Data centers, commercial offices, manufacturing plant machine wiring, banking server rooms, industrial electrical substations.

Key Benefits & Advantages:
• Solid steel enclosure provides continuous physical protection against impacts, dust, and rodents.
• Internal longitudinal steel dividers allow power and data cables to run in the same raceway without interference.
• Pre-punched mounting holes and smooth deburred return edges ensure snag-free cable pulling.
• Available in pre-galvanized (GI), hot-dip galvanized (HDG), and powder-coated finishes.

How Vaishno Storage Solution Manufactures This System: Cold-formed from prime steel sheet into rigid U-channels with matching covers and divider ribs at our Mundka facility.

How We Install on Site: Mounted onto walls, machine bases, or suspended from ceilings with threaded rod trapeze hangers.

Recommended Applications & Operating Environments

Data centers, commercial offices, manufacturing plant machine wiring, banking server rooms, industrial electrical substations.

Request Factory Quote

Direct Mundka plant rates & 2D CAD layout.

+91
Direct Factory Technical Desk
+91-9871431337
Mon–Sat: 9:00 AM – 7:00 PM | Fast Response
SPECIFICATIONS OF RACEWAYS Factory Standard
TOTAL LOAD CAPACITY
300 TO 1500 KG / LEVEL (UP TO 4000 KG HEAVY DUTY)
Parameter Specification Details
Material Specifications Pre-Galvanized (GI) Sheet, CRCA Steel, Hot-Dip Galvanized, Stainless Steel
Sheet Metal Gauge 14 Gauge (2.0 mm), 16 Gauge (1.6 mm), 18 Gauge (1.2 mm), 20 Gauge (1.0 mm)
Standard Widths 50 mm, 75 mm, 100 mm, 150 mm, 200 mm, 300 mm, 400 mm, 600 mm
Standard Depths (Heights) 25 mm, 38 mm, 50 mm, 75 mm, 100 mm
Standard Length 2,500 mm (2.5 meters) per section
Internal Compartments Single, 2-Compartment, or 3-Compartment (segregating Power, Data, and Fire Alarm lines)
Cover Fastening Snap-on tool-free cover or captive M5 zinc-plated machine screws on 300 mm centers
Surface Treatment 7-Tank Pre-Treatment + High-Impact Electrostatic Powder Coating or Pre-Galvanized
Configuration Matrix

Available Sizes & Variants

Model / Size Load Capacity Recommended Application
Floor Trunking Raceway (150x50 mm / 3 Compartment) Segregated Power, Data & Telecom cables Corporate office underfloor cabling & workstation power delivery
Industrial Wall Raceway (200x75 mm / Heavy GI) Heavy industrial control & motor cables Manufacturing plant walls, machine wiring & panel feeds
Substation Heavy Duty Raceway (300x100 mm) High-voltage armoured power cables Power distribution substations, solar plants & data centers

Raceways B2B Price Benchmark

Parameter Vaishno (Factory Direct) Trader Reseller
Price ₹280 – ₹850 per running meter +18% to +30% higher
Steel Grade Prime IS 2062 Grade certified (Tata/JSW) Re-rolled unverified
Paint Finish 7-Tank + 80µ powder coat Air-dry spray paint
CAD Layout Free 2D/3D certified layout within 24h Rough estimates
Rigging Crew Factory-certified riggers with anchors Unskilled labor
Eliminates distributor markups with verified GST input tax credit.
Factory Direct Fabrication from Mundka, West Delhi

Direct Fabrication & Testing

All upright columns, horizontal step beams, and steel deck panels are manufactured at our Mundka facility using automated multi-station roll-forming lines and precision CNC slot punching. Sourced exclusively from Tata Steel, JSW, and SAIL with verified Mill Test Certificates (MTC).

Fast Logistics & Turnkey Erection

Our structural installation crews serve warehouses across Delhi NCR, Haryana, UP, Rajasthan, and Punjab with on-site laser leveling, optical plumb inspection, and certified heavy-duty floor chemical anchoring.

Dispatch: 24–48 Hours Call Factory Engineer
Engineering Standards

How We Manufacture & Install Raceways

Manufacturing at Mundka Plant

  • 1
    Prime Steel Profiling High tensile IS 2062 Grade E250 / E350 steel slitted and inspected for yield strength consistency.
  • 2
    CNC Cold Roll-Forming Automated multi-stand cold roll forming lines produce continuous profiles with precise 50 mm pitch perforations.
  • 3
    7-Tank Chemical Pre-Treatment Hot alkaline degreasing, derusting, water rinses, and zinc phosphating create superior powder bonding and rust resistance.
  • 4
    Electrostatic Powder Coating Thermosetting epoxy-polyester powder applied at 70–80 microns and baked at 200°C for industrial scratch resistance.

On-Site Turnkey Installation

  • 1
    Floor Slab & Laser Plumb Check Optical laser levels assess warehouse concrete floor flatness, expansion joints, and plumb lines prior to erection.
  • 2
    Heavy Duty Chemical / Mechanical Anchoring Base plates secured with M12/M16 high-grade anchor bolts embedded into the industrial concrete floor slab.
  • 3
    Safety Locks & Cross-Bracing Spring-loaded safety pins prevent accidental beam dislodgement from forklift contact, supplemented by horizontal and diagonal cross-ties.
  • 4
    Load Testing & Signage Sign-Off Rigorous deflection checks under live weight followed by affixing certified UDL load capacity safety signboards.

How Raceways Compares

Our raceways feature precision-punched mounting holes and burr-free deburred return edges, ensuring smooth cable pulls without cutting wire insulation.

Factors Determining Raceways Cost

Cross-section dimensions (width x depth), steel gauge thickness (1.2 mm to 2.5 mm), single vs multi-compartment, and surface finish.
Technical FAQs Direct Engineering Answers

Raceways Frequently Asked Questions

Direct answers on load carrying capacity, deflection limits, fabrication lead times, and site installation.

Our 2-compartment and 3-compartment raceways include full-height continuous steel barrier partitions that physically and electromagnetically isolate 415V/230V AC power cables from sensitive CAT6 data and telephone cables.

Standard raceway sections are manufactured in 2,500 mm (2.5 meters) lengths, supplied complete with pre-punched connector coupler plates and zinc-plated fasteners.

Yes. For floor-level trunking, we manufacture heavy-gauge (14 gauge / 2.0 mm) raceways fitted with anti-skid chequered plate covers or heavy recessed covers that support heavy foot traffic and hand trolleys.

Yes. We manufacture factory-engineered 90-degree horizontal elbows, vertical inside/outside risers, tee-junctions, cross-junctions, and end caps that match exact raceway profiles.
Knowledge Base

Warehouse Guides

All Guides →

Technical articles on warehouse layout planning, safety compliance, and load calculations.

Praveen Sharma, Chief Storage Design Engineer Oct 2026
Heavy Duty Pallet Racks: Types, Specifications, Price Per Pallet & Warehouse Layout Guide (2026)

An essential 2026 buying guide for warehouse and plant managers on heavy duty pallet racks: load cap...

Read Guide →
Manish Gupta, Principal Structural Engineer Oct 2026
Industrial Mezzanine Floor Cost Per Sq Ft in India: Load Ratings, Height Clearance & Steel Fabrication (2026)

A detailed technical 2026 guide to industrial mezzanine floor costs in India (₹220 to ₹580/sq ft): h...

Read Guide →
Rajesh Sharma, Senior Fabrication Head Oct 2026
Slotted Angle Storage Racks: Standard Sizes, Gauge Thickness, Weight Capacity & Price Per Rack (2026)

A practical 2026 buying guide for warehouse and retail storage: slotted angle rack standard sizes, s...

Read Guide →